Help > Setting up the COMtrexx
Setting up the COMtrexx
Requirements:
Single Sign-On (SSO) access from Auerswald
Access data and serial number of the COMtrexx
COMtrexx has at least version 2.2.1




Proceed as follows:
1.Activate the proxy service in the COMtrexx.
COMtrexx web interface > Administration > VoIP
Proxy server for Online services > Use proxy
Proxy server for Online services > SIP proxy: proxy.auerproxy.de
2.Copy the serial number of the COMtrexx.
COMtrexx web interface > Dashboard
Status information > Serial number > copy
3.Log in with your Single Sign-On (SSO) access at COMtrexx Control Center.
4.Add the COMtrexx as a system and copy the associated confirmation code (token).
COMtrexx Control Center web interface > Systems
Name > assign freely
Serial number > insert from the COMtrexx
Save
Authorisation status - Token > copy
*Note: The confirmation code is valid for 24 hours and can be renewed if necessary: >
5.Confirm the access in the COMtrexx.
COMtrexx web interface > Administration > Service > External access
Access for COMtrexx Control Center > Confirm access
Confirmation code > insert from the COMtrexx Control Center
OK
*Note: The access for the COMtrexx Control Center can be deleted at any time on the COMtrexx side.
6.Optional: Activate the monitoring in the COMtrexx.
COMtrexx web interface > Administration > Service > External access
Access for COMtrexx Control Center > Monitoring
Recording of system data > OK > OK
Save
7.Optional: Allow remote configuration via (Auerswald) Remote Access (ARA) Server.
COMtrexx web interface > Administration > Service > External access
Access for COMtrexx Control Center > Remote configuration via remote access server in the Internet
Save
8.Optional: Assign authorisations to other users in your company for access to the set-up COMtrexx.
COMtrexx Control Center web interface > Authorisations
Users > select from the list of users in your company
Roles > select and thus set the authorisation level
System > select the set-up COMtrexx
Save